 Agilent 33120A Function/Arbitrary Waveform Generator
Data Sheet
* * * *
15 MHz sine and square wave outputs Sine, triangle, square, ramp, noise and more 12-bit, 40MSa/s, 16,000-point deep arbitrary waveforms Direct digital synthesis for excellent stability Internal AM, FM, FSK and burst modulation make it easy to modulate waveforms without the need for a separate modulation source. Linear and log sweeps are also built in, with sweep rates selectable from 1 ms to 500 s. GPIB and RS-232 interfaces are both standard, plus you get full programmability using SCPI commands. Optional phase-lock capability The Option 001 phase lock/TCXO timebase gives you the ability to generate synchronized phase-offset signals. An external clock input/output lets you synchronize with up to three other 33120As or with an external 10-MHz clock. Option 001 also gives you a TCXO timebase for increased frequency stability. With accuracy of 4 ppm/yr, the TCXO timebase make a 33120A ideal for frequency calibrations and other demanding applications. With Option 001, new commands let you perform phase changes on the fly, via the front panel or from a computer, allowing precise phase calibration and adjustment. Link the Agilent 33120A to your PC The included Agilent IntuiLink software allows you to easily create, edit, and download complex waveforms using the IntuiLink Arbitrary Waveform Editor. Or you can capture a waveform using IntuiLink Oscilloscope or DMM and send it to the 33120A for output. For programmers, ActiveX components can be used to control the instrument using SCPI commands. IntuiLink provides the tools to easily create, download, and manage waveforms for your 33120A. To find out more about IntuiLink, visit www.agilent.com/find/intuilink. The 33120A can also be used in conjunction with the 34811A BenchLink Arb software. This Windows(R)-based program lets you create and edit waveforms on your PC and download them to the 33120A.
Uncompromising performance for standard waveforms The Agilent Technologies 33120A Function/Arbitrary Waveform Generator uses direct digital-synthesis techniques to create a stable, accurate output signal for clean, lowdistortion sine waves. It also gives you fast rise- and fall-time square wave, and linear ramp waveforms down to 100 Hz. Custom waveform generation Use the 33120A to generate complex custom waveforms such as a heartbeat or the output of a mechanical transducer. With 12-bit resolution, and a sampling rate of 40 MSa/s, the 33120A gives you the flexibility to create any waveform you need. It also lets you store up to four 16,000deep waveforms in nonvolatile memory. Easy-to-use functionality Front-panel operation of the 33120A is straightforward and intuitive. You can access any of ten major functions with a single key press or two, then use a simple knob to adjust frequency, amplitude and offset. To save time, you can enter voltage values directly in Vp-p, Vrms or dBm.
Waveforms
Standard Sine, square, triangle, ramp, noise, sin(x)/x, exponential rise exponential fall, cardiac, dc volts. 8 to 16,000 points 12 bits (including sign) 40 MSa/s Four (4) 16,000 waveforms
Output Characteristics
Amplitude (into 50) Accuracy (at 1 kHz) < 100 kHz 100 kHz to 1 MHz 1 Mz to 15 MHz 50 mVpp - 10 Vpp
[1]
Sweep Type Direction Start F/Stop F Speed Trigger Rear Panel Inputs Ext. AM Modulation External Trigger/ FSK/Burst Gate 5 Vpk = 100% modulation 5k input resistance TTL low true Linear or Logarithmic Up or Down 10 mHz - 15 MHz 1 ms to 500 s 0.1% Single, External, or Internal
1% of specified output 1% (0.1 dB) 1.5% (0.15 dB) 2% (0.2 dB) Ampl 3Vrms 3.5% (0.3 dB) Ampl < 3Vrms
Flatness (sinewave relative to 1 kHz)
Arbitrary Waveform length Amplitude resolution Sample rate Non-volatile memory
Output Impedance Offset (into 50) [2] Accuracy Resolution Units Isolation Protection Modulation AM Carrier -3dB Freq. Modulation Frequency Depth Source
50 (fixed) + 5 Vpk ac + dc 2% of setting + 2 mV 3 digits, amplitude and offset Vpp, Vrms, dBm 42 Vpk maximum to earth Short circuit protected 15 Vpk overdrive < 1 minute
Frequency Characteristics
Sine Square Triangle Ramp White noise Resolution Accuracy 100 Hz - 15 MHz 100 Hz - 15 MHz 100 Hz - 100 kHz 100 Hz - 100 kHz 10 MHz bandwidth 10 Hz or 10 digits 10 ppm in 90 days, 20 ppm in 1 year, 18C - 28C < 2 ppm/C < 10 ppm/yr
System Characteristics[3]
Configuration Times[4] Function Change: [5] Frequency Change: [5] Amplitude Change: Offset Change: Select User Arb: 80 ms 30 ms 30 ms 10 ms 100 ms
Modulation Parameter Change: <350 ms 10 MHz (typical) any internal waveform including Arb 10 mHz - 20 kHz 0% - 120% Internal/External any internal waveform including Arb 10 mHz - 10 kHz 10 mHz - 15 MHz Internal only 10 mHz - 50 kHz 10 mHz - 15 MHz Internal/External (1 MHz max.) 5 MHz max. 1 to 50,000 cycles or infinite -360 to +360 10 mHz - 50 kHz 1% Internal/External Gate Single, External or Internal Rate [1] 100 mVpp - 20 Vpp into open circuit [2] Offset 2x pk - pk amplitude [3] Times are typical. May vary based on controller performance [4] Time to change parameter and output the new signal. [5] Modulation or sweep off [6] Times for 5-digit and 12-digit numbers [7] For 4800 baud, multiply the download times by two; For 2400 baud, multiply the download times by four, etc. [8] Time for 5-digit numbers; for 12-digit numbers, multiply the 5-digit numbers by two
Temp. Coeff Aging
Arb Download Times over GPIB
Arb Length Binary ASCII Integer ASCII Real[6] 16,000 points 8 sec 81 sec 100 sec 8,192 points 4 sec 42 sec 51 sec 4,096 points 2.5 sec 21 sec 26 sec 2,048 points 1.5 sec 11 sec 13 sec Arb Download Times over RS-232 at 9600 Baud:[7] Arb Length 16,000 points 8,192 points 4,096 points 2,048 points Binary 35 sec 18 sec 10 sec 6 sec ASCII Integer ASCII Real[8] 101 sec 134 sec 52 sec 69 sec 27 sec 35 sec 14 sec 18 sec
Sinewave Spectral Purity
Harmonic distortion dc to 20 kHz 20 kHz to 100 kHz 100 kHz to 1 MHz 1 MHz to 15 MHz DC to 1 MHz 1 MHz to 15 MHz DC to 20 kHz Phase noise -70 dBc -60 dBc -45 dBc -35 dBc < -65 dBc < -65 dBc + 6 dB/octave <0.04% <-55 dBc in a 30 kHz band
FM Modulation Frequency Deviation Source FSK Internal rate Frequency Range Source Burst Carrier Freq. Count Start Phase Internal Rate Gate Source Trigger
Spurious (non-harmonic)
Total harmonic distortion
Signal Characteristics
Squarewave Rise/Fall time Overshoot Asymmetry Duty cycle Triangle, Ramp, Arb Rise/Fall time Linearity Setting Time Jitter 40 ns (typical) <0.1% of peak output <250 ns to 0.5% of final value <25ns < 20 ns 4% 1% + 5ns 20% to 80% (to 5 MHz) 40% to 60% (to 15 MHz)
2
Option 001 Phaselock/TCXO Timebase
Timebase Accuracy Setability Stability Aging
General
110V/120V/220V/240V 10% Power Line Frequency 45 Hz to 66 Hz and 360 Hz to 440 Hz Power Consumption 50VA peak (28 W average) Operating Environment 0C to 55C Storage Environment -40C to 70C State Storage Memory Power Off state automatically saved, 3 User Configurable Stored States Interface IEEE-488 and RS-232 standard Language SCPI - 1993, IEEE-488.2 Dimensions (W x H x D) Bench top 254.4mm x 103.6mm x 374mm Rack mount 212.6mm x 88.5mm x 348.3mm Weight 4 kg (8.8 lbs) Safety Designed to UL-1244, CSA 1010, EN61010 EMC Tested to MIL-461C, EN55011, EN50082-1 Vibration and Shock MIL-T-28800, Type III, Class 5 Acoustic Noise 30 dBa Warm-up Time 1 hour Warranty 1 year Power Supply
< 0.01 ppm 1 ppm 0 - 50 < 2ppm in first 30 days (continuous operation) 0.1 pm/month (after first 30 days)
External Reference Input Lock Range 10 MHz 50 Hz Level -10 dBm to + 15 dBm +25 dBm or 10 Vpp max input Impedance 50 2%, 42 Vpk isolation to earth Lock Time < 2 seconds Internal Reference Output Frequency 10 MHz Level > 1 Vpp into 50 Phase Offset Range Resolution Accuracy Trigger Output Level Pulse Width Fanout + 360 to - 360 0.001 25 ns 5V zero-going pulse > 2s typical Capable of driving up to three 33120As
Ordering Information Agilent 33120A Function/Arb Generator Opt. 001 Phase Lock/TCXO Timebase Option
103.6 mm 254.4 mm 374.0 mm
88.5 mm 212.6 mm 348.3 mm
3
Ordering Information 33120A Function/Arbitrary Waveform Generator Accessories included Operating manual, service manual, quick reference guide, IntuiLink connectivity software, test data, and power cord
Options Opt. 001 Phase lock/TCXO timebase Opt. 106 BenchLink Arb software (34811A) Opt. 1CM Rack Mount Kit (34190A)* Opt. 910 Extra manual set
Agilent Technologies' Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent's overall support policy: "Our Promise" and "Your Advantage." Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products.
By internet, phone, or fax, get assistance with all your test & measurement needs Phone or Fax United States: (tel) 800 829 4444 Canada: (tel) 877 894 4414 (fax) 905 282 6495 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) (31 20) 547 2323 (fax) (31 20) 547 2390 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (82 2) 2004 5004 (fax) (82 2) 2004 5115 Latin America: (tel) (305) 269 7500 (fax) (305) 269 7599 Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 6836 0252 Email: tm_asia@agilent.com Online Assistance:
Manual language options (please specify one) ABA US English ABD German ABE Spanish ABF French ABJ Japanese ABZ Italian ABO Taiwan Chinese AB1 Korean
Accessories Agilent 34161A Accessory pouch Agilent 34811A BenchLink Arb software
*For racking two side-by-side, order both items below Lock-link Kit (P/N 5061-9694) Flange Kit (P/N 5063-9212)
ww.agilent.com/find/assist
Agilent Email Updates
www.agilent.com/find/emailupdates Get the latest information on the products and applications you select.
Product specifications and descriptions in this document subject to change without notice. Windows(R) is a U.S. registered trademark of Microsoft Corporation. (c) Agilent Technologies, Inc. 2001, 2004 Printed in USA, May 1, 2004 5968-0125EN
This datasheet has been download from: www..com Datasheets for electronics components.


▲Up To Search▲   

 
Price & Availability of 33120A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X